Language: Chinese line English

Titanium alloy fan

  • Titanium alloy industrial fan
  • Titanium alloy industrial fan
Titanium alloy industrial fanTitanium alloy industrial fan

Titanium alloy industrial fan

  • Product description: 1. Titanium fan has excellent anti-corrosion performance.
    2. Compared with ordinary stainless steel, titanium has higher corrosion resistance.
    3. Titanium encountered smoke nitric acid wil
  • INQUIRY
Working principle

According to the principle of converting kinetic energy into potential energy, the titanium fan uses a high-speed rotating impeller to accelerate the gas, then decelerates and changes the flow direction to convert the kinetic energy into potential energy pressure. In a single-stage centrifugal fan, the gas enters the impeller from the axial direction, the gas is converted to the radial direction by the impeller, and then enters the diffuser. In the diffuser, the gas changes the direction of flow, causing deceleration, converting kinetic energy into pressure energy. The pressure increase occurs mainly in the impeller, followed by the diffusion process. In a multi-stage fan, a flow reducer is used to bring the air into the lower impeller, creating a higher pressure.

Titanium fan is the 1 kind of machinery that relies on input mechanical energy to increase gas pressure and transport gas side by side, and it is the 1 kind of driven fluid machinery. The impeller and shell of the centrifugal fan are made of aluminum alloy, which is light in weight and has good corrosion resistance.

Product parameters

Drive Mode

Rotate Speed
(r/min)

Total Pressure
(pa)

Air Quantity
(m3/h)

Effect(%)

Required Power
(kw)

Power
(kw)

9

D

1450

4933
4923
4854
4776
4698
4599
4482
4374

12519
14084
15649
17214
18779
20344
21908
23473

81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4

24.69
27.35
29.97
32.67
35.45
38.12
40.86
43.79

30

45

10

D

1450

6090
6071
6002
5894
5796
5678
5531
5394

17173
19320
21466
23613
25759
27906
30053
32199

81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4

41.82
46.27
50.83
55.31
59.99
64.55
69.18
74.08

55

75

11.2

D

1450

7640
7620
6522
7394
7277
7120
6943
6767

24127
27143
30158
33174
36190
39206
42222
45238

81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4

73.70
81.60
89.49
97.48
105.82
113.71
122.01
130.57

110

132

Repair

Titanium fan start and stop or operation, once found abnormal situation, should immediately check; centrifugal fan operation if found small common fault, should immediately find the cause and solve. If common faults cannot be removed or major common faults are found, please ask the after-sales service staff of the technical professional centrifugal fan to check and maintain. The centrifugal fan shall be terminated during all regular inspections and maintenance of the centrifugal fan. The grease of the centrifugal fan is replaced on time, especially after each disassembly and repair.

If there is a fault in the operation of the titanium fan, it is found that the fan flow has changed, it should be adjusted in time. If the flow is too large or too small, the throttling device should be used to adjust; when the titanium fan starts and stops or runs, once an abnormal phenomenon is found, it should be checked immediately. If a small or medium fault is found in the operation of the fan, the cause should be found out immediately and handled. If the fault cannot be eliminated or a major fault is found, professional fan after-sales personnel can be asked to check and repair; if there is any inspection or maintenance during fan operation, the fan should be stopped; the fan should be replaced with lubricating oil regularly, especially every time it is removed.

When the titanium fan is running normally, it is necessary to avoid the manual failure caused by improper maintenance. In order to prevent natural failures and accidents in all aspects of the titanium fan and motor, give full play to the performance of the equipment, and extend the service life of the equipment, it is necessary to strengthen the daily maintenance of the fan.
1. If the flow change is found during the use of the fan, it should be adjusted in time. If the flow is too large or too small, the throttling device should be used to adjust.
2. When the titanium fan starts and stops or runs, if any abnormal phenomenon is found, it should be checked immediately.
3. If a minor fault is found during the operation of the fan, the cause should be immediately identified and handled. If the fault cannot be eliminated or a major fault, please professional fan after-sales personnel to check and repair.
4. Fan inspection and maintenance, should stop the fan work.
Regularly replace the fan lubricating oil, especially after each repair.

Scan the qr codeClose
the qr code